143 anleitung probeneinfuehrung probeax EN 202506 FINAL instructions for surgeons

Readable documentation excerpt. Open the original PDF for all tables, figures and complete instructions.

Text extraction may differ from the original layout. Follow the manufacturer’s current instructions.

Page 1

EN Instructions ProbeAX Evolution OR Instructions: Opening the packaging and introducing the sample without contamination 1. 2. 3. 4. 5. The ProbeAX Evolution tube comes in two Access the blister pack by pulling Carefully peel off the backing of the blister Remove the ProbeAX Evolution tube and Carefully place your tissue sample in the layers of packaging: the first is a securely the outer packaging apart along pack so that the ProbeAX Evolution tube hold it vertically while unscrewing the cap. ProbeAX Evolution tube so that the sample sealed blister pack that fully encloses tube, the designated open line. rests freely in the package cavity – do not In order to prevent contamination, please be is resting on the ceramic block and is and the second is a protective peel pack. touch or contaminate the tube during this careful not to touch the inside of the tube or completely covered by the liquid. Please This system reliably protects the contents process. the threading. use a representative tissue sample roughly from contamination. the size of a hazel nut (approx. 500 mg). PRODUCT AL0511-B ProbeAX Evolution, double packed, blister pack with NaCl Headquarters Axon Lab AG Affiliates Täfernstrasse 15 Austria info@axonlab.at Netherlands info@axonlab.nl 6. 7. 12284A 062025 CH-5405 Baden-Dättwil Belgium info@axonlab.be Poland info@axonlab.pl Once you have carefully and thoroughly closed

Page 1

CH-5405 Baden-Dättwil Belgium info@axonlab.be Poland info@axonlab.pl Once you have carefully and thoroughly closed In the lab, homogenise the sample using the corresponding Croatia info@axonlab.hr Slovenia info@axonlab.si the tube, your sample is ready for transport to homogeniser, keeping the tube closed throughout the entire Czech Republic info@axonlab.cz Switzerland (de) info@axonlab.ch the lab. Please ensure that you have threaded process. Doing so will protect the sample from contamination Germany info@axonlab.de Switzerland (fr) info_f@axonlab.ch the cap onto the tube securely and accurately. up until it is analysed. This IVDR-compliant system ensures www.axonlab.com Luxembourg info@axonlab.lu improved sample quality and faster results.