Automated slide staining

DAGATRON DX-300

A slide-staining platform with a dedicated compartment for each slide and fresh reagent delivered by precision nozzles. The selected instrument configuration determines the available microbiology or haematology protocols.

Request a technical proposal

Include the product and reference you need in the enquiry form.

DAGATRON DX-300

In the daily workflow

01

Individual slide processing

Each slide sits in an individual compartment. Nozzles apply fresh reagent to limit cross-contamination.

02

Match the protocol to the application

Gram, Ziehl-Neelsen, Kinyoun, fluorescence and selected haematology stains. Available protocols vary by configuration.

03

Plan the complete setup

Evaluation covers the instrument, staining reagents, cleaning solution and quality-control materials.

Technical profile

The details.
Clearly stated.

Manufacturer
Dagatronics
Capacity
1–20 slides; Ziehl-Neelsen: 1–10
Program memory
Up to 3 programs per staining protocol
Safety
Integrated ventilation
Warmer
Integrated slide warmer
Reagents
Level and consumption monitoring
Combinations
Two or three protocols, depending on configuration

Manufacturer-stated cycle times

Staining protocols

Gram

10 slides
6 min
20 slides
11 min

Capacity up to 20 slides

Ziehl-Neelsen

10 slides
11 min
20 slides
—

Capacity up to 10 slides

Kinyoun

10 slides
14 min
20 slides
19 min

Capacity up to 20 slides

Fluorescence

10 slides
10 min
20 slides
15 min

Capacity up to 20 slides

Wright-Giemsa

10 slides
6 min
20 slides
9 min

Capacity up to 20 slides

May Grünwald-Giemsa

10 slides
15 min
20 slides
17 min

Capacity up to 20 slides

Source: DAGATRON brochure 01/2025. Times vary by staining program.

Ordering references

References & variants

DX300-MBSGR00GramAxonlab · 12089402
DX300-MBSZN00Ziehl-NeelsenAxonlab · 12091143
DX300-MBSFL00FluorescenceAxonlab · 12091142
DX300-MBSKN00KinyounAxonlab · 12091144
DX300-MBMGZ00Gram + Ziehl-Neelsen + KinyounBrochure reference
DX300-MBDGF00Gram + fluorescenceBrochure reference
DX300-HMSWR00Wright-GiemsaBrochure reference
DX300-HMSMG00May Grünwald-GiemsaBrochure reference

Sources & technical file

Documentation
for your evaluation.

Product brochures, instructions for use and manufacturer documentation.

DAGATRON DX-300 brochure · 01/2025 · Microbiology collection pp. 6–9

Official Axonlab listings
  • www.axonlab.com/product/dagatron-dx-300-for-gram-12089402
  • www.axonlab.com/product/dagatron-dx-300-for-ziehl-neelsen-12091143
  • www.axonlab.com/product/dagatron-dx-300-for-fluorescence-12091142
  • www.axonlab.com/product/dagatron-dx-300-for-kinyoun-12091144
Request a technical proposal

Include the product and reference you need in the enquiry form.

Staining protocols and times

The June 2025 brochure lists Gram, Ziehl-Neelsen, Kinyoun, Fluorescence, Wright-Giemsa and May Grünwald-Giemsa, depending on the model. Gram: 6 minutes for 10 or 11 minutes for 20 slides. Ziehl-Neelsen: up to 10 slides, 11 minutes for 10. Kinyoun: 14/19 minutes for 10/20 slides. Fluorescence: 10/15 minutes. Wright-Giemsa: 6/9 minutes. May Grünwald-Giemsa: 15/17 minutes. The selected configuration determines the available protocols.

Original documents (2)
Ask about this product

FROM THE DEMONSTRATIONS

The workflow in practice.

Ventilation

The DX-300 demonstration shows integrated ventilation: reagent gases pass through a carbon filter before exhaust. Confirm installation requirements, filter maintenance and exact model with Medical Trade.

Custom programmes

The demonstration shows staining-program customisation for laboratory needs. The June 2025 brochure specifies storage for up to three custom programmes.

Warming and cleaning

The DX-300 presentation shows the stainer combined with a slide warmer and integrated cleaning/drying functions. The brochure also describes an integrated slide warmer and cleaning. Follow the required maintenance and laboratory control procedures.